18" (455mm) long, 1-1/2" (38mm)dia. tubing. Constructed of 18-gauge (1.2mm), type 304 satin-finish stainless steel tubing. Concealed mounting flange 1/8" (3mm) thick, type 304...
Search Results "Transfer Platform"
Commonly Searched Documents
- Bobrick 18" Straight Grab Bar B-6806 x 18
- Bobrick 18" Straight Grab Bar B-5806 x 18
- Bobrick 18" Straight Grab Bar Peened B-5806.99 x 18
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
Recreation Facilities [§206.2.9 – §206.2.17]
– §206.2.17] The ADA Standards also address accessible routes to amusement rides, boating facilities, bowling lanes, court sports, exercise machines and equipment, fishing piers and platforms...
-
11B-408.4.3 Platform to hoistway clearance
The platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3....
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings....
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports....
-
1007.2 Continuity and components
Platform lifts complying with Section 1007.5. Horizontal exits. Smoke barriers....
-
Evaluation of transfers
These types of transfers were not evaluated in our study. ...
-
iv. Lifts
Lifts Medical providers may need lifts to transfer some patients with mobility disabilities safely to examination or treatment tables or chairs or to gurneys or hospital beds....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
M305.2.5 Surface Hazards
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges....
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2....
-
M305 Supports
[See subsections ...]
-
M305 Supports
[See subsections ...]
-
M305.2.4 Cross Section (Section-by-Section Analysis)
The proposed rule did not provide specific requirements for the cross section of transfer supports....
-
4.1.3(5)*
EXCEPTION 4: Platform lifts (wheelchair lifts) complying with 4.11 of this guideline and applicable state or local codes may be used in lieu of an elevator only under the following conditions...
-
3. Lift Compatibility Exception
[Overhead lifts] may offer flexibility over a portable lift because it can transfer the patient from either side placing the patient in the desired imaging orientation, and the ability to...
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports....
- Figure 610.3 Extent of Seat – Drawing from the U.S. Access Board
-
Clear Floor and Turning Space Inside Examination Rooms
The exam table must have sufficient clear floor space next to it so that an individual using a wheelchair can approach the side of the table for transfer onto it....