Shear force induced in a fastener or mounting device from the application of 250 lbf (1112N) shall be less than the allowable lateral load of either the fastener or mounting device or the supporting...
Search Results "Support Rail"
Commonly Searched Documents
-
4.26.3(3)
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device, or supporting...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or supporting...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Classroom Acoustics: ADA Standard Section 6.
Review the updated information on the revisions to the ADA Standards regarding classroom acoustics.
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
11B-307.2 Protrusion limits
For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance....
- Inpro Corporation IPC® HR9 Northern Hardwoods® Real Wood Handrail
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. ...
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. ...
-
4.26.3(4)
a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal load between the fastener and the supporting...
-
"Public entity.'' (Preamble, Section-by-Section Analysis)
district, or other instrumentality of a State or States or local government; and the National Railroad Passenger Corporation, and any commuter authority (as defined in section 103(8) of the Rail...
-
1012.2 Height
Exceptions: For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, both as applicable in Section 101.2, guards whose top rail also serves...
-
Are detectable warnings required on curb ramps or at hazardous vehicular areas?
Under the ADA Standards, which apply primarily to facilities located on sites, detectable warnings are required at transit facilities (at curb ramps and along open drop-offs of rail station...
-
Public entity (Section-By-Section Analysis and Response to Comments)
district, or other instrumentality of a State or States or local government; and the National Railroad Passenger Corporation, and any commuter authority (as defined in section 103(8) of the Rail...
-
Research Issues
NIH Mission As you all probably know, much of the biomedical research in the United States is supported by the NIH....
- seca 664 - electronic wheelchair scale_without comments - seca1840
-
E207.1 General
EXCEPTION: Software that is assistive technology and that supports the accessibility services of the platform shall not be required to conform to the requirements in Chapter 5....
-
601.1 Scope (Section-by-Section Analysis)
601.1 Scope (Section-by-Section Analysis) This section proposes that the technical requirements for support documentation and services in this chapter be applied where either (a) required...
-
Alterations to cells. (Section-by-Section Analysis)
Only one commenter expressed support for Option I, and a handful of commenters supported Option III. The comments on each option are discussed below....
- Rakks® Brackets Installation Video
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
Comments should include information on sources to support the dimensions, where possible....