Ramps complying with Section 1012, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
Search Results "Play Area Ramp"
-
1009.2, Item 8
-
Wet Conditions [§405.10]
Wet Conditions [§405.10] Landings subject to wet conditions must be designed to prevent the accumulation of water. Landings are permitted slopes not steeper than 1:48 to allow for...
-
Horizontal Dispersion: ADA Standard Section 221.2.3.1
Section 221.2.3.1 covers scoping requirements in the current ADA Standards for horizontal Dispersion in assembly areas.
-
4f.
Is a level landing, at least 60 inches by 60 inches, provided where a ramp changes direction? [ADA Stds 4.8.4] Yes _____ No _____...
-
4.8.5(5)
(5) Top of handrail gripping surfaces shall be mounted between 34 in and 38 in (865 mm and 965 mm) above ramp surfaces....
-
Cubicles and Counters: ADA Standard Section 231.4.1
Section 231.4.1 covers scoping requirements in the current ADA Standards for cubicles and counters.
-
Accessible Routes to Tiered Dining Areas in Sports Facilities
Accessible Routes to Tiered Dining Areas in Sports Facilities....
-
231.4 Visiting Areas
231.4 Visiting Areas. Visiting areas shall comply with 231.4....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed.
-
4.1.6(3)(a)(i)
(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
Performing Areas
Performing areas include spaces typically elevated or depressed and used primarily for purposes of entertainment, including stages, arena floors, and orchestra pits....
-
R207.2 Alterations
In alterations where existing physical constraints prevent compliance with R207.1, a single diagonal curb ramp shall be permitted to serve both pedestrian street crossings....
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
-
11B-246.4 Day use areas and vista points
Day use areas, vista points, and similar areas shall be accessible....
-
11B-246.4 Day use areas and vista points
Day use areas, vista points, and similar areas shall be accessible....
-
11B-246.4 Day use areas and vista points
Day use areas, vista points, and similar areas shall be accessible....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...