Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Expected Maximum Flight Duration"
-
11B-705.1.1.2 Dome spacing
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
703.2.7 Character Spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
E. Reporting, Recordkeeping, and Other Compliance Requirements
As discussed in section V.A.3 above, the Department expects that the additional cost and burden of noting which screenings will be captioned or audio-described is de minimis when a movie...
-
2.1(a)(iii) Substantially Limits
its nature and severity; how long it will last or is expected to last; its permanent or long term impact, or expected impact....
-
Annualized Costs of New Accessibility Requirements for OTRBs
7% Discount Rate $549 $971 $1,513 As this table demonstrates, the cost of the new OTRB accessibility requirements are expected...
-
4.1.2. Upfront Costs
Overall, the upfront costs to movie theaters are expected to total $34.2 million when discounted at 7 percent....
-
11B-805.7 Built-in cabinets and work surfaces
Since there is no change to the wording of Section 11B-805.7, there is no reason to expect that OSHPD will change its interpretation....
-
11B-805.7 Built-in cabinets and work surfaces
Since there is no change to the wording of Section 11B-805.7, there is no reason to expect that OSHPD will change its interpretation....
-
SUMMARY OF PRELIMINARY REGULATORY ANALYSIS
On the benefits side, the Preliminary RIA estimates likely incremental benefits by monetizing the value of three categories of benefits expected to accrue from the proposed 508 Standards...
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-303.5 Warning curbs
A warning curb is not required when a guard or handrail is provided with a guide rail centered 2 inches (51 mm) minimum and 4 inches (102 mm) maximum above the surface of the walk or sidewalk...
-
11B-1008.4.3 Play tables
The tops of rims, curbs, or other obstructions shall be 31 inches (787 mm) high maximum....
-
11B-303.5 Warning curbs
A warning curb is not required when a guard or handrail is provided with a guide rail centered 2 inches (51 mm) minimum and 4 inches (102 mm) maximum above the surface of the walk or sidewalk...
-
Shower Spray Controls
accessible bathtubs and shower compartments, sections 607.6 and 608.6 of the 2010 Standards require shower spray controls to have an on/off control and to deliver water that is 120°F (49°C) maximum...
-
R305.1.1 Dome Size
The truncated domes shall have a base diameter of 23 mm (0.9 in) minimum and 36 mm (1.4 in) maximum, a top diameter of 50 percent of the base diameter minimum and 65 percent of the base...
-
R302.7.4 Flangeway Gaps
Flangeway gaps at pedestrian at-grade rail crossings shall be 64 mm (2.5 in) maximum on non-freight rail track and 75 mm (3 in) maximum on freight rail track....
-
4.8.2* SLOPE AND RISE
The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
11B-608.5.1 Reserved
transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum...
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...