Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
Search Results "Car Ramp"
-
11B-505.7.1 Circular cross section
- citEcar ADA Electric Shuttle 11P 1WC
- citEcar ADA Enclosed Shuttle 11P 1WC
-
R304.5.1.1 Pedestrian Circulation Paths Other Than Shared Use Paths
In pedestrian circulation paths other than shared use paths, the clear width of curb ramp runs, blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
-
810.5.3 Platform and Vehicle Floor Coordination
rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192 or 49 CFR part 38, mini-high platforms, car-borne...
-
Top Landing [§406.4]
Top Landing [§406.4] The required landing at the top of curb ramps allows an accessible route to connect to the ramp opening....
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
Level changes greater than ½ inch high would be required to be ramped....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
407.4.8.2 Audible Indicators
Audible indicators shall comply with 407.4.8.2.
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
407.4.8.2 Audible Indicators
Audible indicators shall comply with 407.4.8.2.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
407.4.8.2 Audible Indicators
407.4.8.2 Audible Indicators. Audible indicators shall comply with 407.4.8.2.
-
409.4.6.1 Size
409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
11B-411.3.1 Type
Elevator door type shall comply with Section 11B-407.3.1.
-
14. In § 38.93(d)(3)
§ 38.93 [Amended] 14. In § 38.93(d)(3), remove the period at the end of the paragraph and add the following words: “,ensuring compliance with section 37.42, where applicable.” in...
-
18. In § 38.125, amend the first sentence of paragraph (a)(2)
§ 38.125 [Amended] 18. In § 38.125, amend the first sentence of paragraph (a)(2) by adding the words “level-entry boarding,” before the words ” portable or platform lifts” and by...
-
409.4.6.2 Location
409.4.6.2 Location. Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control...