A telephone and emergency signal device shall be provided in the car....
Search Results "Car Dimension"
-
11B-409.4.7.1 Type
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
Bus boarding and alighting areas
Bus boarding and alighting areas must be in compliance with the ADA-ABA Guidelines (Section 810.2), which address surfaces (sturdy), dimensions (96" long x 60" wide); connection to sidewalks...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
12162(a)(4)(A)(ii)
Unless not practicable, a person providing intercity rail transportation shall place an accessible car adjacent to the end of a dining car described in clause (I) through which an individual...
-
12181(2) Commercial facilities
Such term shall not include railroad locomotives, railroad freight cars, railroad cabooses, railroad cars described in section 12162 of this title or covered under this subchapter, railroad...
-
F104.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
104.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces ...
-
1011.2.4 Openings
Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
407.2.2 Hall Signals
Hall signals, including in-car signals, shall comply with 407.2.2....
-
11B-408.4.5 Illumination
Elevator car illumination shall comply with Section 11B-407.4.5....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
408.4.8 Emergency Communications
Car emergency signaling devices complying with 407.4.9 shall be provided....
-
408.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
11B-411.4.4 Leveling
Elevator car leveling shall comply with Section 11B-407.4.4....
-
407.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....