Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
Search Results "Counter Slope"
Commonly Searched Documents
-
§ 38.95(c)(3) Ramp threshold
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Guest Bathrooms
located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground. 806.2.4.1 Vanity Counter...
-
1134A.6 Showers
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
M303.3.2 Beveled (Section-by-Section Analysis)
proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required to be beveled with a slope...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
406 Curb Ramps
These include specifications for running slope, surface, clear width, and wet conditions. Consistent with the scope of the guidelines, these requirements apply to facilities on sites....
-
E. Chapter 4: Boarding and Alighting
Responses to comments on the Board’s proposal in the 2010 NPRM to revise the technical requirements for the slope of ramps in non-rail vehicles by specifying a single standard (1:6) for...
-
Dispersion
Clustering wheelchair spaces is allowed only where sight line slopes exceed 5%, such as bleachers and balconies (or in alterations where dispersion is technically infeasible)....
-
Summary of Significant Changes
Revised Requirements for Maximum Running Slope of Ramps: The 2016 Non-Rail Vehicle Guidelines revise and simplify the existing guidelines regarding running slope for ramps in non-rail vehicles...
- Neo-Metro Commercial Wall Mounted Neo-Basin 8935 Series
- Oval Window Audio Portable InfoLoop Hearing System
- ASI Global Partitions Plastic Laminate Partitions
-
4(6)
The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage. ...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
f-v
[ADA Standards § 4.8.4] Yes No Note: if the running slope is less than 1:16 but more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing]....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
4d.
[ADA Stds 4.8.4] Yes _____ No _____ Note: When the running slope is less than 1:16 and more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing....
-
6d. Ramp Length
[ADA Stds 4.8.4] Note: When the running slope is less than 1:16 and more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing. Yes _____ No _____...
-
Table Surface Height
These commenters recommended that where only a portion of counters are made accessible, the accessible height should be 31 inches maximum....
-
Clear Floor Space [4.2.4]
A clearance at least 27 inches high and 19 inches deep is necessary for a person using a wheelchair to pull-up to tables and counters....
-
A4.1.1(3) Areas Used Only by Employees as Work Areas
., laboratories, service counters, ticket booths), 5%, but not less than one, of each type of work station should be constructed so that an individual with disabilities can maneuver within...