The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
Search Results "Vertical Actuation Bar"
-
907.4.2.2 Height
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
11B-221.2.1.5 Stadium-style movie theaters
Located within the area of the theater in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for...
-
11B-221.2.1.5 Stadium-style movie theaters
Located within the area of the theater in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing angles for...
-
1016.5 Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on outdoor recreation access routes can be obstacles....
-
Addendum C: Participant responses to two step transfers for protocols D and E
Avoid/Avoid Depends on the situation and whether there are grab bars....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
f-viii
If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
6g. Ramp Edge Protection
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
4g.
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Stds 4.8.7] Yes _____ No _____...
-
A4.9.1 Minimum Number
Only interior and exterior stairs connecting levels that are not connected by an elevator, ramp, or other accessible means of vertical access have to comply with 4.9....
-
1.2.4
1.2.4 When local horizontal discontinuities and vertical alignments are measured according to Section 1.1.9 a recommended tolerance is ±1/8 in. (3 mm)....
-
Sec.36.403(f)(2)(ii)
(ii) Costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls;...
-
§ 35.151(b)(4)(iii)(B)(2)
(2) Costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls;...
-
§ 36.403(f)(2)(ii)
(ii) Costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls;...
-
A4.34.5 BATHROOMS
Although not required by these specifications, it is important to install grab bars at toilets, bathtubs, and showers if it is known that a dwelling unit will be occupied by elderly or severely...
-
§ 35.151(b)(4)(iii)(B)(2)
(2) Costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls;...
-
d-vii
If the ramp or landing has a vertical drop-off on either side of the ramp, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
M305.2.2 Structural Strength
Transfer supports and their connections shall be capable of resisting vertical and horizontal forces of 250 pounds (1,112 N) applied at all points on the transfer support....