217.2 Wheelchair Accessible Telephones. Where public telephones are provided, wheelchair accessible telephones complying with 704.2 shall be provided in accordance with Table...
Search Results "Self-Closing Door"
Commonly Searched Documents
-
217.2 Wheelchair Accessible Telephones
-
11B-217.2 Wheelchair accessible telephones
Where public telephones are provided, wheelchair accessible telephones complying with Section 11B-704.2 shall be provided in accordance with Table 11B-217.2. Exception: Drive-up...
-
11B-217.2 Wheelchair accessible telephones
Where public telephones are provided, wheelchair accessible telephones complying with Section 11B-704.2 shall be provided in accordance with Table 11B-217.2. Exception: Drive-up...
-
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B
Comparison of Single-User Toilet Room “Pairs” With Fixtures Side-by-Side: Plan 1A and Plan 1B 1991 Standards Plan-1A Pair: 1991 Standards with Out-Swinging Doors...
- Mockett DH401-BB Slim Barrel Door Handle Back to Back
- Hager Companies Round Offset Door Push/Pull Set 24Q
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
- Mockett DH5/BB Large Cylindrical Door Handle Back to back
- Mockett DH4/BB Slim Cylindrical Door Handle Back to back
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
Features of an Accessible Examination Room
Accessible entry door has 32” minimum clear opening width with door open 90 degrees. 7. Maneuvering clearances are needed at the door to the room....
-
1011.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1011.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
1013.4, Item 1
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.”...
-
Required for All Public Entities
[See subsections ...]
-
Sample Documents
Public Notice - long and short versions Under Title II all public entities must provide information to the public, program participants, applicants and employees about the...
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
- Hager Companies Round Offset Door Push/Pull Set 21
- Hager Companies Round Offset Door Push/Pull Set 22
- SOSS Door Hardware Invisible Hinge Installation Video