(3) Costs associated with providing accessible telephones, such as relocating a telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY);...
Search Results "Riser Height"
-
§ 35.151(b)(4)(iii)(B)(3)
-
703.5.7 Stroke Thickness
Stroke thickness of the uppercase letter "I" shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
§ 36.403(f)(2)(iii)
(iii) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum....
-
§ 35.151(b)(4)(iii)(B)(3)
(3) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY...
-
221.2.2 Integration
For example, it would be unacceptable to place only the wheelchair spaces, or only the wheelchair spaces and their associated companion seats, outside the seating areas defined by risers...
-
11B-106.5 Defined terms
PLATE KITCHEN OR KITCHENETTE LAVATORY MAIL BOXES MARKED CROSSING MAY MEZZANINE MULTIBEDROOM HOUSING UNIT NFPA NOSING OCCUPANT LOAD OCCUPIABLE SPACE OPEN RISER...
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-407.2.1.3 Clear floor or ground space
The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-608.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
Appendix Two: Design Information and Accommodation Models
Research findings on Occupied Height Type of WhMD user Sam-ple Size Mean (SD) Min 5%ile 10%ile Me-dian 90%ile 95%ile Max...
-
§382.133(e)(2)
(2) The maximum weight and dimensions (length, width, height) of the device to be used by an individual that can be accommodated in the aircraft cabin consistent with FAA safety requirements...
-
4.34.5.2(2)
(2) The height of the water closet shall be at least 15 in (380 mm), and no more than 19 in (485 mm), measured to the top of the toilet seat....
-
308 Reach Ranges
In the final rule, the maximum side reach has been lowered to the height specified for forward reaches....
-
Base Support [No specific provision—affects M303.2.4]
To discuss the maximum base support height, the sub-committee looked at anthropomorphic data regarding footrest heights....
- Westside Center for Independent Living - Los Angeles, Santa Monica, CA
-
Obstacles [1018.5]
When beach access routes are constructed of concrete, asphalt, or boards, obstacles cannot exceed one-half inch in height at their highest point....
-
Data Deficiencies
Data Deficiencies Advocates on the committee, representing the interests of people with disabilities, strongly stated that a 17” height is essential to accommodate the largest segment...
-
11B-705.1.1.1 Dome size
warning surface shall have a base diameter of 0.9 inch (22.9 mm) minimum and 0.92 inch (23.4 mm) maximum, a top diameter of 0.45 inch (11.4 mm) minimum and 0.47 inch (11.9 mm) maximum, and a height...