Handrail extensions are required on the top landing of the stairs but are not required at the bottom landing. Handrails on pool stairs must comply with ADAAG provisions....
Search Results "Ramp Landing"
Commonly Searched Documents
-
Handrails
- Detecto 485 Series Stationary Wheelchair Scale
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum....
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1-½ inch (38 mm) maximum....
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
Do limits on protruding objects apply to stairways?
Yes, requirements for protruding objects are not limited to accessible routes and apply to all circulation paths, including stairways and their landings....
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum....
-
68.10(22) Public Right-of-Way
(22) Public Right-of-Way--Public land or property, usually in interconnected corridors, that is acquired for or dedicated to transportation purposes....
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum....
-
Beveled: ADA Standard Section 303.3
Section 303.3 covers the current ADA Standards for beveled level changes.
-
11B-405.9.2 Curb or barrier
To prevent wheel entrapment, the curb or barrier shall provide a continuous and uninterrupted barrier along the length of the ramp....
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
407.4.3 Platform to Hoistway Clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
1.1.3.2, Item 18
Marine Oil Terminals regulated by the California State Lands Commission. See Section 1.14 for additional scope provisions....
-
4.10.11 Illumination Levels
The level of illumination at the car controls, platform, and car threshold and landing sill shall be at least 5 footcandles (53.8 lux)....
-
106.5.31 Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
4.10.11 ILLUMINATION LEVELS
The level of illumination at the car controls, platform, and car threshold and landing sill shall be at least 5 footcandles (53.8 lux)....
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
- State of California Disability Access Services (DAS) - Boost Your Business: Physical Access, Technical Assistance & CASp
-
409.4.3 Platform to Hoistway Clearance
The clearance between the car platform and the edge of any landing sill shall be 1 1/2 inch (38 mm) maximum....
-
Gangway
A variable-sloped pedestrian walkway that links a fixed structure or land with a floating structure. Gangways that connect to vessels are not addressed by this document....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....