Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
Search Results "One Step Entry"
-
11B-1008.4.2 Clear floor or ground space
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
502.4 Platform Accessibility Features
Section 9.3.3 Enable sequential entry of multiple (chorded) keystrokes; B. Section 9.3.4 Provide adjustment of delay before key acceptance; C....
-
502.4 Platform Accessibility Features
Section 9.3.3 Enable sequential entry of multiple (chorded) keystrokes. 2. Section 9.3.4 Provide adjustment of delay before key acceptance. 3....
-
11B-608.2.2 Standard roll-in type shower compartments
30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides and shall have a 60 inches (1525 mm) wide minimum entry...
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
Additional Parking Spaces for Residents: ADA Standard Section 208.2.3.2
Section 208.2.3.2 covers scoping requirements in the current ADA Standards for additional parking spaces for residents.
-
STORY
A story containing one or more mezzanines has more than one floor level....
-
STORY
A story containing one or more mezzanines has more than one floor level....
- Corbin Russwin Inc. FE5400S Mult-Point Exit Device Latching System
- Spectrum Aquatics Glacier Platform Pool Lift
-
11B-220.1.2 Two automatic teller machines or fare machines
Where two automatic teller machines or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-707.3,...
-
11B-220.1.2 Two automatic teller machines or fare machines
Where two automatic teller machines or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-707.3,...
-
1008.3 Transfer Systems
Moving between a transfer platform and a series of transfer steps requires extensive exertion for some children....
-
Appendix: Checklist for APR Installations
Once installation is complete, the installer should perform the following steps, for each APS at the intersection: Check the location of the APS; Is it close to the crosswalk it controls...
-
Play Components
For the purpose of the guidelines, ramps, transfer systems, steps, decks, and roofs are not considered play components....
-
1008.3 Transfer Systems
Moving between a transfer platform and a series of transfer steps requires extensive exertion for some children....
-
II. SPECIFIC ACTION TO BE TAKEN BY OLYMPIA:
In order to resolve this matter, Olympia agrees to take the following additional steps to remove barriers to access at Joe Louis Arena according to the deadlines stated below. ...
-
TTYs: ADA Standard Section 217.4
Section 217.4 covers scoping requirements in the current ADA Standards for TTYs.
-
Central Holding Cells: ADA Standard Section 231.3.1
Section 231.3.1 covers scoping requirements in the current ADA Standards for central holding cells.
-
11B-213.3.4 Lavatories
Where lavatories are provided, at least 10 percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment....
-
11B-213.3.4 Lavatories
Where lavatories are provided, at least 10 percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment....
- Acoustiguide Opus+ Multimedia Guiding System
-
FAQ: How do I invite members to join my WorkGroup?