Board made four significant changes to this section: two significant changes to accommodate the unique challenges of mammography equipment; one significant change to the ramped running slope...
Search Results "Cross Slope"
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
-
K. Eating Areas
Eating Areas An accessible route, at least 36 inches wide and without steps or steep slopes, must be provided to and throughout the food service and eating areas of the shelter....
-
7.4.9 Trail Facilities
When the surface of the required clear ground space for trail facilities is not paved or is not elevated above the natural ground, slopes not steeper than 1:20 (5 percent) shall be permitted...
-
4.2.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Where Ramps and Curb Ramps are Required [§303.4]
Portions of accessible routes with running slopes steeper than 5% also must be treated as ramps....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....
-
§ 38.83(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
§ 38.125(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. Advisory 11B-403.6 Handrails....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Angled or rounded nosings or sloped risers help prevent this hazard and provide a smoother transition. Straight risers without nosings are acceptable....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
11B-504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Passing Spaces [1016.4]
When passing spaces and resting intervals overlap, the technical requirements for resting intervals apply and the slope of the surface must be no steeper than 1:48 (2 percent) in any direction...
-
R302.5.5 Regulatory Constraints
As proposed in the NPRM, R302.5 would require the grade of pedestrian access routes contained within a street or highway right-of-way, except at pedestrian street crossings, to not exceed...
-
ADA Basic Building Blocks Course - Project of the ADA National Network
Topics in Course - 12 Purpose of the ADA (8 pages) Structure of the ADA (3 pages) Enforcement of the ADA (5 pages) Cross-cutting Issues - Definition of Disability...
-
Issue: Curb Ramps
Likewise, when new sidewalks or walkways are built or altered, they must contain curb ramps or sloped areas wherever they intersect with streets or roads....
-
1. Start with Comprehensive Planning and Site Selection
A site survey, even for sites considered “flat” or without substantial change in elevation, should be conducted to design for a continuous accessible route, with compliant cross slope and...
-
General Exceptions in FSTAG
Access Board for identifying when extreme environmental barriers may exempt an entire trail from technical accessibility requirements: A combination of running slope and cross slope...
-
6.10
lines of sight comparable to those for members of the general public, and (b) include wheelchair spaces as an integral part of the fixed seating plan, (c) provide the appropriate depth for cross...
-
F236.1 General
Where operators provide a biceps curl machine and cable-cross-over machine, both machines are required to meet the provisions in this section, even though an individual may be able to work...
-
R209.1 General
Where pedestrian signals are provided at pedestrian street crossings, they shall include accessible pedestrian signals and pedestrian pushbuttons complying with sections 4E.08 through 4E...
-
Stacks [8.5]
Recommendation: Dimensions for turns around obstructions in 4.3.3 (ADAAG Figure 7) provide minimum space for maneuvering around stacks where a cross aisle at the end of stacks is not provided...
-
11B-221.2.1.5 Stadium-style movie theaters
The required wheelchair spaces shall be located on risers or cross-aisles in the stadium section that satisfy at least one of the following criteria: Located within the rear 60 percent...