Elevator cars shall provide a clear floor space of 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum and shall comply with 305....
Search Results "Clear Width at Turn"
-
409.4.1 Inside Dimensions of Elevator Cars
- Guide for Home Remodeling for People with Disabilities and Special Needs: What You Need to Know
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
What is the Minimum Width for Non-Level Boarding?
[49 CFR §§ 37.9, 37.41-37.43, 38.125] June 16, 2015
-
405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302. Changes in level are not permitted. ...
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302. Changes in level are not permitted....
-
4.31.2 Clear Floor or Ground Space
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted....
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
305.2 Floor or Ground Surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-806.2.3.1 Personal lift device floor space
In transient lodging facilities, clearance for the use of a personal lift device shall be provided under the bed(s) and adjacent to the clear floor space required by Section 11B-806.2.3....
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
4.31.2 CLEAR FLOOR OR GROUND SPACE
A clear floor or ground space at least 30 in by 48 in (760 mm by 1220 mm) that allows either a forward or parallel approach by a person using a wheelchair shall be provided at telephones...
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...