(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
6.3(3)
-
7. Clear Width
(Note: wheelchairs need 36" of clear passage width) [28 CFR 36.304(b)(4)] Yes __ No __ N/A __ Comments: ___________________________________________...
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
Components of Accessible Routes
[See subsections ...]
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
203.9 Employee Work Areas
Although areas used exclusively by employees for work are not required to be fully accessible, consider designing such areas to include non-required turning spaces, and provide accessible...
-
10.2.1(2)
, new or replaced bus shelters shall be installed or positioned so as to permit a wheelchair or mobility aid user to enter from the public way and to reach a location, having a minimum clear...
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
- Access Board: Sales and Service Counters
-
B. Question 2: Section 904.4.1 and Clear Counter Space
The inquiry into whether a sales or service counter satisfies Section 904.4.1’s length requirement turns on the length of the counter as built, not on the length of “clear” counter space...
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
Priority 3: Toilet Rooms
Word Fillable Form (2.4MB) Word Non-Fillable Form (2.2MB) PDF Non-Fillable Form (0.7MB)
-
1003.3.1 Boat Slip Clearance
Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
1003.3.1 Boat Slip Clearance
Boat slips shall provide clear pier space 60 inches (1525 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
11B-1003.3.1 Boat slip clearance
Boat slips shall provide clear pier space 60 inches (1524 mm) wide minimum and at least as long as the boat slips....
-
Exercise Machines and Equipment
Section 236 of the 2010 Standards requires at least one of each type of exercise machine to meet clear floor space requirements of section 1004.1....
-
§ 38.23(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches by 48 inches....
-
4.1.3 Wheelchair Seating Space
Clear floor or ground space that is at least 30 inches by 48 inches shall be provided at each seating space that is required to be accessible and positioned for a forward approach to the...
-
H13
Is the operating control (switch, lever, button, or pull) of at least one of each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor...
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear...
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3.