Substantive changes to this section include: removal of references to water coolers (602.1) requiring all wheelchair accessible drinking fountains to provide knee and toe...
Search Results "Water Closet Centerline"
-
602 Drinking Fountains
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Gangways
gangways are provided as part of accessible routes to connect floating accessible fishing piers or platforms, the following exceptions to ADAAG have been included to deal with the varying water...
-
Accessible Pool Stairs
Accessible Pool Stairs Accessible pool stairs are designed to provide assistance with balance and support from a standing position when moving from the pool deck into the water and out...
-
Footrests and Armrests
Armrests are not required, however if provided, the armrest opposite the water must be removable or be able to fold clear of the seat when the seat is in the raised (load) position....
-
Sinks [F212.3, Exception 2]
When hot water is provided, the drainpipes at sinks and lavatories must be wrapped, insulated, or shielded to help prevent a person using a mobility device from accidentally touching the...
-
11B-1005.2.1.1 Dispersion
Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank....
-
11B-1005.2.1.1 Dispersion
Different fishing locations may provide varying water depths, shade (at certain times of the day), vegetation, and proximity to the shoreline or bank. ◼...
- Aqua Creek Products Mobi Chair Floating Beach Wheelchair
- Patriot Portable Lift by Aqua Creek Products
-
11B-805 Medical care and long-term care facilities
Touch screen units shall be allowed to be vertically mounted with the centerline of the display screen no more than 52 inches above the floor in compliance with Section 11B-707.7.1.1....
-
11B-404.2.9 Door and gate opening force
At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the...
-
11B-404.2.9 Door and gate opening force
At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the...
- Georgia-Pacific Compact® Splash Blue Vertical Double Roll Coreless Tissue Dispenser 56789
-
11B-212.3 Sinks
A fixed bowl or basin with running water and drainpipe, as in a kitchen or laundry, for washing dishes, clothing, etc. (As differentiated from the definition of "Lavatory".). ...
-
11B-212.3 Sinks
A fixed bowl or basin with running water and drainpipe, as in a kitchen or laundry, for washing dishes, clothing, etc. (As differentiated from the definition of "Lavatory".). ...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Gangway Slope and Rise Exceptions
For example, where the vertical distance between where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level is 4 feet, the gangway...
-
Soiltac Powder Mix-In
There was no constructed drainage mechanisms that would be considered appropriate in the trail construction industry for this surface, therefore the water runoff from the adjacent earth...
-
StaLok
After the heavy rainfall, the only noticeable factor was pooling of the water on the lower points of the surface; StaLok is impervious so it repels the water....
-
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis)
For example, if a server is located on a tall rack in a maintenance closet accessed only by service personnel, the controls on the server need not be accessible....
-
[ADA Titles II & III] Primary Function
Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, _|ADA Title III: and restrooms|_ are not areas containing...
-
Guestroom Doors
Requirements: All doors and doorways (except shallow closets) into and within all guestrooms and suites (including guestroom bathrooms, kitchens, and connecting room doors) shall provide...