examination tables.11 Several women dismissed as unhelpful step stools or the step built into fixed height tables, including a woman with paraplegia from the long-term effects of childhood...
Search Results "Table Height"
Commonly Searched Documents
-
2.2 Evidence of Physical Accessibility Barriers
-
4. Perspectives of Equipment Types
The other group is those tables used on X-Ray system....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
- Spectrum Industries Inc. Freedom One Sit-to-Stand Lectern™
-
11B-211.2 Minimum number
The 2022 California Plumbing Code (CPC), Table 4-1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-221.2.1.1 General seating
Wheelchair spaces complying with Section 11B-802.1 shall be provided in accordance with Table 11B-221.2.1.1....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
Rationale for the recommendation Imaging tables need some form of support on the opposite side of the table....
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Front View
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Plan View
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet Side View
-
Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet Front Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Addition
An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
M301.2.2 Transfer Surface Size
All X-Ray tables meet the 28 inch table width for item “B”....
-
Attachment J
The toilet’s centerline is 19 inches from the side wall, the toilet seat height is 20 inches, and the flush valve control is located on the closed side of the toilet. ...
-
101.2 Scope
Exception: Detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory structures...
-
Priority 4: Additional Access - Drinking Fountains, Public Telephones & Fire Alarms
Word Fillable Form (0.7MB) Word Non-Fillable Form (0.6MB) PDF Non-Fillable Form (0.4MB)
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
Patients access diagnostic imaging tables from one of the long sides of the table. Some imaging equipment have narrow tables due to functional necessity....
-
Stroke Thickness: ADA Standard Section 703.2.6
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
11B-703.2.6 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
11B-703.8.6 Stroke width
Low resolution VMS characters shall comply with the pixel count for stroke width in Table 11B-703.8.5....
-
Boat Slips: ADA Standard Section 235.2
Section 235.2 covers scoping requirements in the current ADA Standards for boat slips.
- "Clear" Customized Hearing Healthcare