404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2 mentions that changes in level that do not exceed those permitted in section 303.3 are acceptable in "required clear...
Search Results "Clear Tread Width"
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
-
1012.3 Other Vehicles
Parking spaces for vehicles, other than recreational vehicles, shall be 16 feet (4880 mm) wide minimum. EXCEPTION: Where two adjacent parking spaces are provided for vehicles,...
-
1012.3 Other Vehicles
Parking spaces for vehicles, other than recreational vehicles, shall be 16 feet (4880 mm) wide minimum. EXCEPTION: Where two adjacent parking spaces are provided for vehicles,...
-
Van Space: Wider Access Aisle
Van Space: Wider Access Aisle
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
Provide accessible routes with a minimum clear width of 36 inches at all points, except as provided in the ADA Standards, where the width may decrease to 32 inches for a distance of no more...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
11B-804.6.6 Refrigerator/freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
804.6.6 Refrigerator/Freezer
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...
-
Table 2: Summary of Department of Transportation Survey
0.49% +0.5% 7 Curb ramp, flare slope 0 5% 0.57% +0.5% 8 Curb ramp gutter counterslope 0 5% 0.58% +0.5% 9 Widths...
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable....
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable....
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Single-User Toilet Rooms: Side Transfer Space
Clear floor space should be centered at lavatories. This clear floor space, which can overlap space required at water closets, must extend 17 to 19 inches below the lavatory....
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
Features of Accessible Parking Spaces
If the accessible route is located in front of the parking space, install wheel stops to keep vehicles from reducing the clear width of the accessible route below 36 inches. 3....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....