The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
Search Results "Clear Opening"
Commonly Searched Documents
-
1134A.7, Item 1
- DORMA ED700 Low-Energy Swing Door Operator
- Besam PowerSwing Electro-hydraulic Swing Door Operator BIM
- Besam SW200i Overhead Concealed Swing Door Operator for Dual Egress BIM
- Besam SW200i Overhead Concealed Swing Door Operator for Dual Egress
- Besam SW200i-IG In Ground Swing Door Operator, Center Pivot, Double Door
-
Inpro Corporation JointMaster® AR Series Seal Expansion Joint Systems
Requires the Premium User plan or above. (Login or upgrade your account!)
- Besam PowerSwing Electro-hydraulic Swing Door Operator
-
Inpro Corporation JointMaster® DR Series Seal Expansion Joint Systems
Requires the Premium User plan or above. (Login or upgrade your account!)
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
- Theatre Access NYC
- Access Board: Clear Floor Space Position
-
§ 38.95(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
- Figure 1003.3.2 (Exception 2) Edge Protection at Boarding Piers – Drawing from the U.S. Access Board
- Figure 1003.3.1 Boat Slip Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.2 Boarding Pier Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.1 (Exception 2) Edge Protection at Boat Slips – Drawing from the U.S. Access Board
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1.
-
Obstructions
Obstructions “Obstructions” are also prohibited by TAS 604.3.2 within the required water closet clearance. An obstruction is any element that violates the protruding object...
-
K1
K1. Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the food service and eating areas (it may narrow to 32 inches wide...
-
4.2.2 Width for Wheelchair Passing
The minimum width for two wheelchairs to pass is 60 in (1525 mm) (see Fig. 2).
-
4.2.2 WIDTH FOR WHEELCHAIR PASSING
The minimum width for two wheelchairs to pass is 60 in (1525 mm) (see Fig. 2).
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1.
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1.