Search Results "Table Height"
Commonly Searched Documents
- 308.3.1 Automatic Trash Can Height
-
Serving Counters
Serving Counters Where food or drinks are served at counters and the counter height is more than 34 inches above the floor, providing a lowered section of the serving counter at least...
-
5.7 File a Lawsuit
Though these were inconveniences, the biggest issue was the lack of an accessible exam table. I was not able to get onto your exam table without being lifted. ...
-
Clear Floor Space [4.2.4]
A clearance at least 27 inches high and 19 inches deep is necessary for a person using a wheelchair to pull-up to tables and counters....
-
11B-224.4 Guest rooms with communication features
In transient lodging facilities, guest rooms with communication features complying with Section 11B-806.3 shall be provided in accordance with Table 11B-224.4....
-
Width: ADA Standard Section 407.3.6
Section 407.3.6 covers the current ADA Standards for elevator door width.
-
AISLE
[DSA-AC] A circulation path between objects such as seats, tables, merchandise, equipment, displays, shelves, desks, etc., that provides clearances in compliance with this code....
-
Caroma® USA Sydney Low Profile 270 Easy Height Round Front Plus Toilet Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-703.2.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”....
- Inclusion Solutions Model 2000 Voting Booth with Light (Hard Curtain)
- Inclusion Solutions Model 2000 Voting Booth (Hard Curtain)
-
902 Dining Surfaces and Work Surfaces
Clear floor space is required for a forward approach (902.2), and a surface height of 28 to 34 inches is specified (902.3)....
-
Two Step Transfer Evaluation
Additionally, the study participants who made the two-step transfers appear more able on these transfers when comparing the heights achieved during the two-step transfers to the heights...
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
-
Transfer Steps: ADA Standard Section 1009.5.4
Transfer step height shall be 8 inches (205 mm) maximum....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
11B-308.4 Suggested reach ranges for children
Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions of Table 11B-308.4 shall be permitted....
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with 806.2 shall be provided in accordance with Table 224.2....
-
2.6 Conspicuity Ratings
Thus, for each sidewalk, the sum of the heights of the bars is 100 percent....
-
3.2 MDE Advisory Committee Process
In totality, the 5 medical equipment subcommittees met 24 times (Table 3.2)....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum....
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....