between stories is required in multi-story government facilities subject to title II of the ADA except those with no more than two stories where the inaccessible story above (or below) the entry...
Search Results "Side Entry"
-
Public Sector (Government) Facilities
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
F231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
231.4.1 Cubicles and Counters
At least 5 percent, but no fewer than one, of cubicles shall comply with 902 on both the visitor and detainee sides....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
4.20.2 Floor Space
Therefore, residential tubs that are only accessed from one open side, were typically designed with one end against a wall and 3 open sides from which assistance could be provided....
-
Water closet
Additional space between the sidewall and the water closet was intended to provide space on both sides of the fixture for a caregiver to stand alongside....
-
4.3.3 Clear Floor Area
side....
-
502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the...
-
502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for angled van parking spaces which shall have access aisles located on the passenger side of the...
-
A4.16.5 Flush Controls
Flush valves and related plumbing can be located behind walls or to the side of the toilet, or a toilet seat lid can be provided if plumbing fittings are directly behind the toilet seat....
-
A4.16.5 FLUSH CONTROLS
Flush valves and related plumbing can be located behind walls or to the side of the toilet, or a toilet seat lid can be provided if plumbing fittings are directly behind the toilet seat....
-
SUMMARY AND CONCLUSIONS
Signalization is used to enhance the operational efficiency of roundabouts where pedestrian traffic causes unacceptable vehicle delay and where the volume of traffic from one entry is so...
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical....
-
§ 36.304(d)(3)(ii)
least 300 linear feet of swimming pool wall, it shall comply with the applicable requirements for swimming pools, except that it shall be required to provide only one accessible means of entry...