Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
Search Results "Line Spacing (Raised)"
-
1009.6.3 Size
-
1009.6.3 Size
Each area of refuge shall be sized to accommodate two wheelchair spaces that are not less than 30 inches by 52 inches (762 mm by 1320 mm)....
- seca 676 r Digital Wheelchair Scale with Handrail and Integrated RS232 Interface
-
Width [4.3.3.] and Passing Space [4.3.4]
However, the minimum width of hallways and corridors is often further determined by ADAAG requirements for clear floor space at elements such as drinking fountains, door maneuvering clearances...
-
Wheelchair Passage Width [4.2.1] and Passing Space [4.2.2]
A minimum width of 30 inches is generally sufficient for stationary space. Additional clearance is needed for maneuvering and sway....
-
703.3.2 Position
If text is multi-lined, braille shall be placed below the entire text....
-
703.3.2 Position
If text is multi-lined, braille shall be placed below the entire text....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
Accessible Ground Surfaces
Accessible Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, and maneuvering spaces, must comply with the American Society for Testing and Materials...
-
Machinery Spaces (§203.5)
Machinery Spaces (§203.5) Spaces used only by service personnel for maintenance, repair, or occasional monitoring of equipment Examples: elevator pits/ penthouses, mechanical/...
-
4.3.3 Clear Floor Area
4.3.3 Clear Floor Area Clear floor area dimensions are the basis for the minimum required size of spaces used by wheeled mobility users (e.g. platform/wheelchair lifts) and for spaces...
-
12162(a)(3)(A)(ii) a number of spaces
(ii) a number of spaces...
-
707.6.2 Numeric Keys
types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line...
-
11B-707.6.2 Numeric keys
types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line...
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
Vertical Dispersion: ADA Standard Section 221.2.3.2
Section 221.2.3.2 covers scoping requirements in the current ADA Standards for vertical dispersion in assembly areas.
- 305.3 Trash Can Clear Floor Space
- 604.3.1 Water Closet Clear Floor Space
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
11B-707.6.2 Numeric keys
types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line...
-
707.6.2 Numeric Keys
types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line...
-
11B-707.6.2 Numeric keys
types of keypads are acceptable, provided the computer-style keypad is organized similarly to the number pad located at the right on most computer keyboards, and does not resemble the line...
-
11B-304 TURNING SPACE
[See subsections ...]
-
11B-304 Turning space.