Section 612.2 covers the current ADA Standards for benches in saunas and steam rooms.
Search Results "Floor Surface"
-
Bench: ADA Standard Section 612.2
- Pilot Rock T-600 Series Caterpillar Picnic Table
- Beneficial Designs
-
407.2.3.1 Floor Designation
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
- Pilot Rock AT Series Traditional A-Frame Picnic Table With Steel Braces - Using Lumber
-
3.3 Guidance on the Visual Properties of Detectable Warnings
Two relatively dark surfaces may provide high luminance contrast, but on asphalt or other dark sidewalk surfaces (with reflectance less than 10 percent) high contrast is not always a good...
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
Test Procedures
It has been correlated to the work measurement done in ASTM F1951, Accessibility of Surface Systems, for a wide array of surfacing and floor coverings....
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door....
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
11B-1008.2.6.2 Use zones
Ground surfaces located within use zones shall comply with ASTM F 1292 (1999 edition or 2004 edition)....
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door....
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door....
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
Clearance: ADA Standard Section 608.2.2.1
Section 608.2.2.1 covers the current ADA Standards for the clearances of standard roll-in type shower compartments.
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).