After traveling over each surface, subjects were asked to subjectively rate each surface and decide whether the surface was acceptable or not....
Search Results "Floor Surface"
-
Executive Summary
- Steelcase Series 3 Height-Adjustable Work Surface with Crank
- Landscape Forms Inc. Morrison Table and Stool Collection Video
- Landscape Forms Inc. Olithas Outdoor Tables and Benches Video
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
Tile Tech Pavers IPE Deck Tiles
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
Non-Circular Cross Sections: ADA Standard Section 505.7.2
Section 505.7.2 covers the current ADA Standards for the non-circular cross section of handrail gripping surfaces.
-
11B-505.7.2 Non-circular cross sections
Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4 inches (102 mm) minimum and 6¼ inches (159 mm) maximum, and a cross-section dimension of...
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
Lavatories Adjacent to Partitions
Although we often times see accessories such as hand dryers or paper towel dispensers installed on the wall adjacent to the lavatory, the accessories cannot encroach into the clear floor...
-
Beds: ADA Standard Section 224.3
Section 224.3 covers scoping requirements in the current ADA Standards for transient lodging guest room beds.
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
11B-904.4.1 Parallel approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum above the finish floor shall be provided....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
Water Hydrants
The surface at the base of water hydrants at recreation areas must be firm and stable with a 60-inch turning radius. See the "Surfaces" rule of thumb above....
-
1008.4.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
-
1008.4.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
-
Applying the Accessibility Standards to the Plan, Installation, and Maintenance of Ground Level Accessible Routes for Playgrounds
Is the surface for the accessible route, clear ground space and turning space compliant with ASTM F1951-99 Standard Specification for Determination of Accessibility of Surface Systems Under...
-
§ 38.83(a)(1) General
) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit at least two wheelchair or mobility aid users to reach areas, each with a minimum clear floor...
-
Chapter 1: Background
Current standards have criteria only related to seat height and clear floor space for wheelchair users (2)....