Five Knuckle - Full Mortise Swing Clear Hinge BB1360 - Ball Bearing - Standard Weight Description: - ANSI A5122 - For square edge doors - Non-rising removable pin with...
Search Results "Edge Protection"
- Hager Companies Five Knuckle - Full Mortise Swing Clear Hinge BB1360
- Hager Companies Three Knuckle - Full Mortise Swing Clear Hinge AB7502
- Hager Companies Three Knuckle - Full Mortise Swing Clear Hinge AB7501
- Hager Companies Five Knuckle - Full Mortise Swing Clear Hinge BB1362
- Hager Companies Five Knuckle - Half Mortise Swing Clear Hinge BB1265
- Stanley F248 Standard Weight Plain Bearing “Swing Clear” Full Mortise Offset Door Hinge
- Hager Companies Three Knuckle - Half Mortise Swing Clear Hinge AB7511
- Hager Companies Three Knuckle - Half Mortise Swing Clear Hinge AB7512
-
Swimming Pools: ADA Standard Section 242.2
Section 242.2 covers scoping requirements in the current ADA Standards for swimming pools.
-
1013.2 Where required
platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge...
-
4.34.3(2)(b) Reach Depth More Than 10 in
Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
Treads and Risers [4.9.2], Nosings [4.9.3]
ADAAG specifies the radius of the curvature of the leading edge of treads and the underside slope of angled or rounded nosings....
-
§ 38.77(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
1134A.7, Item 1
The clear floor space shall extend past the front edge of the water closet at least 36 inches (914 mm). See Figure 11A-9M....
-
§ 38.155(a)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
1015.2 Where required
aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below at any point within 36 inches (914 mm) horizontally to the edge...
-
903 Benches
Commenters recommended clarification on the permitted horizontal distance of the back support from the rear edge of the seat....
-
Bonded Beach Path Installation
At the termination of the path at the waterline a 0.1-m (3.5-in.) curb was formed to reduce any inadvertent rolling of the path into the water and to stiffen the edge directly in contact...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge...
- 2620KL Digital Wheelchair Scale Dual Ramps & Extra-Large Platform
-
Sold to the Highest Bidder: Building Better Auction Houses with Steel
These facilities improve the bidder experience, protect the consignment inventory, and streamline the chaotic flow of auction day....
-
Relationship to Other Laws
Finally, part 36 does not invalidate or limit the remedies, rights, and procedures provided under any Federal, State, or local law (including State common law) that affords greater or equal protection...
-
1007.4 Elevators
Elevators are not required to be accessed from an area of refuge or horizontal exit for smoke protected seating areas complying with Section 1028.6.2....