The handrail requirements in section 505 address specifications for continuity, height, clearance, gripping surface, cross section, fittings, and extensions....
Search Results "Clearance"
Commonly Searched Documents
-
Handrails Requirement
-
Comparison of Single-User Toilet Room Layouts: Plan 3
An out-swinging door also minimizes the overall layout depth and cannot swing over the required clear floor space or clearance at any accessible plumbing fixture....
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. Figure 505.4 Handrail Height...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Facility
Knee and toe clearance complying with 306 shall be providing. (17” min. depth.) 902 Dining Surfaces and Work Surfaces. 902.3 Height....
-
L. Lavatory
Is there at least one lavatory (wash basin) in each public restroom that has each of the following characteristics... ...a 29" high clearance under the front edge and the top of the bowl...
-
G. Chapter 6: Wheelchair Spaces and Securement Systems
The two areas in which the requirements in this chapter differ substantially from the proposed rule—wheelchair space maneuvering clearances and forward excursion barriers for rear-facing...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Where clear floor space at a lavatory is obstructed on both sides more than 2 feet, a clearance at least 36 inches wide is required....
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....
-
11B-505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. ◼...
-
11B-604.5.1 Side wall
2013 CEC) requires a nurse call device at the side wall of a water closet that must be coordinated carefully with the side grab bar at an accessible water closet to ensure that accessible clearances...
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
All objects that protrude from surfaces or posts into circulation paths shall comply with ADA Standards § 4.4 and a minimum 80 inch vertical clearance shall be provided in walks, halls,...
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-T
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-T
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
- Populas Accella Adjustable Activity / Computer Workstation
- Pilot Rock UT Series Side Accessible Picnic Table Using Recycled Plastic
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A circular space is permitted to include knee and toe clearance. A T-shaped space is permitted to include knee and toe clearance only at the end of either the base or one arm....
-
RECOMMENDATIONS
32.7 m Vertical alignment-crest 49.8 m Recumbent bicyclists 46.7 m Refuge islands 2.5 m Bicyclists with trailers 3.0 m Signal clearance...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment. Figure 505.4 Handrail Height...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
505.4 Height
Sufficient vertical clearance between upper and lower handrails, 9 inches (230 mm) minimum, should be provided to help prevent entrapment....