Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
Search Results "Water Closet Grab Bar"
Commonly Searched Documents
-
604.8.1.1 Size
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
Help honor John Wodatch for the ADA's 25th Anniversary !!!
There is a new gofundme effort to raise money to buy accessible play equipment at the John Wodatch Community Playground at the Two Rivers Public Charter School in Washington, DC...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
4. ABSOLUTE DIMENSIONS
For instance, consider the requirement that water closets (toilets) be an absolute 18" from the adjacent wall to the centerline....
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
- Speakman Versatile ADA Hand Shower System VS-1001-ADA-PC
-
Section 2. Bathroom
"Bathroom" means a bathroom which includes a water closet (toilet), lavatory (sink), and bathtub or shower....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-206.2.5 Restaurants, cafeterias, banquet facilities and bars
In restaurants, cafeterias, banquet facilities, bars, and similar facilities, an accessible route shall be provided to all functional areas, including raised or sunken areas, and outdoor...
-
Exceptions When Conditions Do Not Permit Full Compliance
The proposed rule would have permitted exceptions to only certain provisions in the technical requirements when certain conditions do not permit full compliance. The final rule...
-
Birthing Room Bath Tub Accessibility
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 11B-603 (Toilet and Bathing Rooms) through 11B-610 (Seats)....
-
BATHROOM
For the purposes of Chapter 11A and 11B, a room which includes a water closet (toilet), a lavatory, and a bathtub and/or a shower....
-
BATHROOM
For the purposes of Chapters 11A and 11B, a room which includes a water closet (toilet), a lavatory, and a bathtub and/or a shower....
-
BATHROOM
For the purposes of Chapters 11A and 11B, a room which includes a water closet (toilet), a lavatory, and a bathtub and/or a shower....
-
Summary of Major Provisions
requirements address the following outdoor constructed features provided at these facilities: picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water...
- Direct Access Solutions Kit
-
§100.203(c)
It is necessary to reinforce the walls with blocking between studs in order to affix the grab bars....
-
11B-604.8.1.4 Toe clearance
[2010 ADA Standards] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches deep with a wall-hung water closet or 65 inches deep with...