Wheelchair spaces complying with M303.2 shall be provided at diagnostic equipment.
Search Results "Intensive Care Patient Room"
Commonly Searched Documents
-
M303.2 Wheelchair Spaces
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
M303.2.3 Depth
The depth of wheelchair spaces shall comply with M303.2.3.
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...
-
M305.3.3 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to prohibit standing supports from rotating in their fittings. There were no comments on this section and it was not addressed by the MDE Advisory Committee....
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
5.3.3 Transfer Sides Recommendations for M302
5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
Other Safety tips:
Make sure the door closes securely when entering and leaving your room....
-
Brailling Printed Materials
To locate a resource to transcribe printed materials into hardcopy Braille, call local organizations that serve people who are blind or have low vision, independent living centers,...
-
Food Allergies and Sensitivities
According to FARE (Food Allergy and Research Education) “Fifteen million Americans have food allergies – and they are eager to find restaurants [and other venues] that can...
-
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers
Best Practices in the Design of Toileting and Bathing Facilities for Assisted Transfers Final Report August 1, 2001 Jon A. Sanford, Project Director Atlanta Research...
-
Captioning Audio/Visual Materials
The best way to use captioned audio/visual materials is to purchase or use videos that already have closed captions. If this is not possible or videos must be produced in-house,...
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
-
11B-809.10.8.3 Cabinets
Cabinets shall be removable without the use of specialized knowledge and/or tools. The finished floor shall extend to the wall under the lavatory.
-
§ 36.406(c) Places of lodging.
subject to this part shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...