ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, issued Code Application...
Search Results "Floor Plan"
-
11B-805.4.3 Turning space
-
Plan 3A: 12-Foot Wide Accessible Guest Room
Plan 3A: 12-Foot Wide Accessible Guest Room This drawing shows an accessible 12-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Plan 1A: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Plan 1B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Section H: Lifts
(§410.1) H3 Is there 30" by 48" of clear floor space within the lift?...
-
M304.2 Standing Surface (Section-by-Section Analysis)
In preparing the final rule, the Board has determined that as previously drafted this provision unintentionally placed requirements on the facility floor, as opposed to restricting the requirements...
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
-
4.5.6 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
-
11B-809.10.4 Sufficient maneuvering space
Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing....
-
11B-809.10.4 Sufficient maneuvering space
Doors shall be permitted to encroach into the clear floor space or clearance for fixtures where clear maneuvering space is provided outside the arc of the door swing....
-
4.7.8 Utility and Dump Station Hookup Clear Floor or Ground Space
The clear floor or ground space around utility and dump station hookups shall be at least 30 inches (760 mm) by 60 inches (1525 mm)....
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
those with in-swinging doors tend to be larger (in terms of square footage) in order to accommodate clearance for the in-swinging door and, thus, are already likely to have adequate clear floor...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
those with in-swinging doors tend to be larger terms of square footage) in order to accommodate clearance for the in-swinging door and, thus, are already likely to have adequate clear floor...
- FEMA Guidance on Planning for Integration of Functional Needs Support Services in General Population Shelters
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav....
-
§ 38.95(c)(5) Slope
If the height of the vehicle floor, under 50% passenger load, from which the ramp is deployed is 3 inches or less above the station platform a maximum slope of 1:4 is permitted; if the height...
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.6.4 Range or cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with Section 11B-306....
-
5.1 Q...Would the first story of single-story dwelling units over the parking level be required to be accessible?
The Guidelines adopt and amplify the definition of ground floor found in HUD's regulation implementing the Fair Housing Act (see 24 CFR 100.201) to indicate that . . .where the first floor...
-
804.6.4 Range or Cooktop
Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 306....