In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "Flared Side"
Commonly Searched Documents
-
11B-608.3.3 Alternate roll-in type shower compartments
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-602.3 Operable parts
The flow of water shall be activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 mm) of the front edge of the fountain or an automatic...
-
1. Question: What is the minimum width needed for a non-level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
varies from one builder to another, but it is not uncommon for the passenger car edge of the lift platform in the fully deployed position to be a number of inches away from the actual side...
-
4.1.3(17)(a)
Unless otherwise specified, accessible telephones may be either forward or side reach telephones. 2 A bank consists of two or more adjacent public telephones, often installed as a unit...
-
Accessible Round Table Style
Side aisles require at least six feet between the table and the side wall or other obstructions....
-
Segway Human Transporter
Its footprint is not much larger than the human body's and has a handlebar and platform similar to a scooter, but with two wheels side by side....
-
Detectable Warning Surfaces on Curb Ramps (Section-by-Section Analysis)
The Department of Transportation standards require detectable warning surfaces to extend the full width of the curb ramp (exclusive of flared sides) and either the full depth of the curb...
-
610.3.1 Rectangular Seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall. Figure 610.3.1 Rectangular Shower Seat...
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
804.2.1 Pass Through Kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
Clear Floor Space
Because people transfer in different ways, providing additional space both in front of and to side of the ride will increase flexibility and usability for a more diverse population....
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
5. When Is It Important for My Client to Request a Reasonable Accommodation?
Because an employer does not have to excuse failure to meet production standards that are consistently applied, even if the difficulty was caused by a health condition or the side effects...
-
H15
Is at least one wide toilet stall provided with an out swinging door, side and rear grab bars, and clear space next to the toilet?...
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Clear Floor Space [4.27.2]
Clear Floor Space [4.27.2] Clear floor space for a forward or side approach is required at controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed...
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
Size and Clearances [4.21.2]
Recommendation: Twelve inches of additional clear floor space at the seat will facilitate side transfers....
-
404.2.7 Door and Gate Hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides....
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
Maneuvering Clearances [§404.2.4]
Clearance beyond the latch side is not required at entry doors to hospital patient rooms. ...