Unlike traditional designs where the surface sits above the holder, this side-by-side layout creates a more modern and practical look....
Search Results "Flared Side"
Commonly Searched Documents
- Kuriki 2-in-One Paper Holder
- Bobrick B-30929 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
Suspicious Minds Ramp
The ramp leading to the exhibits has a rise greater than 6", but does not have the required handrails on both sides. See Standards § 4.8.5. q....
-
5.1.6 Clear Floor or Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap the trail or ORAR, as applicable, or another clear ground space. Â ...
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
4.8.5* Handrails
If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
11B-610.3.1 Rectangular seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall....
- seca 664 - electronic wheelchair scale_without comments - seca1840
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part...
- Bobrick B-30919 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- Greenfields Outdoor Fitness Two-Person Accessible Combo Butterfly and Reverse Fly GR2005-1-48E-W (2 Configurations)
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
G. Compartment Size
.: diagonal or side approaches)? [ADA Stds. 4.17.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
Are doors or gates to employee work areas required to comply?
Full compliance of doors or gates on the interior side is recommended, but not required....
-
Guidelines for Requirement 5
The inclusion of this additional specification for side approach is consistent with the comparable provisions in the ANSI Standard....
-
11B-504.8 Floor identification
11B-703.2 _|Raised Characters|_, 11B-703.3 _|Braille|_ and 11B-703.5 _|Visual Characters|_ shall be located at the landing of each floor level, placed adjacent to the door on the latch side...