ii. Accessible scales Medical providers often do not weigh individuals who use wheelchairs because they do not have an accessible scale, even though that information is a routine...
Search Results "Elongated Water Closet Seat"
Commonly Searched Documents
-
ii. Accessible scales
-
5.1* General
Except as specified or modified in this section, restaurants and cafeterias shall comply with the requirements of 4.1 to 4.35. Where fixed tables (or dining counters where food is...
-
General [5.1]/ Access Aisles [5.3]
General [5.1]/ Access Aisles [5.3] Access is required to 5% of fixed or built-in tables distributed throughout dining areas. The required clear width (36 inches minimum) is...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Tracks on the tub rim are not allowed as they can interfere with the transfer to tub seats. Dual grab bars on the back wall are needed for transfer to the seat and into the tub....
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
11B-608.5.3 Alternate roll-in type shower compartments
483 mm) maximum from the seat wall or on the back wall opposite the seat 15 inches (381 mm) maximum, left or right, of the centerline of the seat; and shall be located above the grab bar...
-
Wheelchair Spaces (M303.2)
M303.2 would require a wheelchair space to be provided at diagnostic equipment used by patients seated in a wheelchair....
- Inpro Corporation Endurant® Stainless Steel Straight Grab Bar
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
4.1 Wheeled Mobility Device Dimensions
The height of the seat can be measured at the edge and at the middle, under the cushion, or on top of the cushion....
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
This would mean that the wing wall could not extend beyond the front edge of a lavatory located on the other side of the wall from the water closet....
-
11B-608.5.3 Alternate roll-in type shower compartments
wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
DSA IR 16-12: GRAB BAR DESIGN AND CONNECTIONS: 2019 CBC
Disciplines: Structural, Access History: 12/31/2019 Division of the State Architect (DSA) documents referenced within this publication are available on the DSA Publications...
-
General: ADA Standard Section 226.1
Section 226.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dining surfaces and work surfaces.
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
Figure 5.2.3 below indicates how these width and depth dimensions are measured for MDE used by patients in supine, prone, or side-lying positions (M301) and the seated position (M302)...
-
F234.3 Minimum Number
Amusement rides shall provide at least one wheelchair space complying with 1002.4, or at least one amusement ride seat designed for transfer complying with 1002.5, or at least one transfer...
-
234.3 Minimum Number
Amusement rides shall provide at least one wheelchair space complying with 1002.4, or at least one amusement ride seat designed for transfer complying with 1002.5, or at least one transfer...
-
234.3 Minimum Number
Amusement rides shall provide at least one wheelchair space complying with 1002.4, or at least one amusement ride seat designed for transfer complying with 1002.5, or at least one transfer...
-
5.3.3 Transfer Sides Recommendations for M302
This provision will coincide with the seat area design of most examination chairs. NPRM Proposed Provision: M302.2.3 Transfer Sides....