The 1991 Standards, at section 4.24, and the 2010 Standards, at section 606, both require the clear floor space at sinks to be positioned for a forward approach and knee and toe clearance...
Search Results "Bedside Clearance"
Commonly Searched Documents
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
-
1002.4.4.2 Side Entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
Doorways
In the final rule, clarification has been added that the 32 inch minimum clearance applies to those doors "providing user passage" into and within guest rooms not required to be accessible...
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
Q3.) What are the types of “manufacturing processes” that were anticipated where the advisory says “tolerances recognized by this provision include… “those that may be a necessary consequence of a particular manufacturing process”?
Therefore, the manufacturing tolerances and the construction tolerances must both be considered when measuring the clearances between a grab bar and a tile wall....
-
Handrails
Handrails must comply with the following: Clearance between handrail gripping surfaces and adjacent surfaces shall be 1 1/2 inches (38 mm) minimum. ...
-
1002.4.4.2 Side Entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
2.5.2.2 International Organization for Standardization (ISO) Standards
Risk management plays a critical and central role in the design of medical devices, and it also ties into IEC 60601-1 and FDA’s expectations for quality systems and premarket clearance or...
-
Toilet Compartments
The clear floor space required for a baby changing table by TAS 902.2 may overlap the water closet clearance based on TAS 604.3.2 since baby changing tables are considered convenience “fixtures...
-
H29
Accessible Shower Stall Minimum Size and Clearances Accessible Shower Stall Grab Bars and Seat, Shower, and Control Area...
-
1002.4.4.2 Side Entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
Question 16
What is the optimal clearance needed under a bed to accommodate a mechanical lift?...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
reaching over an obstruction in relation to the forward-most point, and the negative range implying that the reach target is brought closer to the person (such as on a table with knee clearance...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
reaching over an obstruction in relation to the forward-most point, and the negative range implying that the reach target is brought closer to the person (such as on a table with knee clearance...
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Requirement: 4.21.2 Size and Clearances. Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b)....
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
-
11B-1002.4.4.2 Side entry
Where wheelchair spaces are entered only from the side, amusement rides shall be designed to permit sufficient maneuvering clearance for individuals using a wheelchair or mobility aid to...
- Just Manufacturing Classroom Concealed Ledgemount Teardrop Handle Faucet
- Just Manufacturing Concealed Classroom Faucet with Triple Radius Spout
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-V
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-P
-
3.0 Comparison of Research Methodologies
The BS8300:2001 research covered knee and toe clearances, reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....