- Delta 1-1/2″ x 18″ ADA Grab Bar, Concealed Mounting 40118-PS
-
4.3.9 Doorway Design
The lack of differences between the findings for the passage task on the pull sides of Doors 1, 800 mm (31.5 in.) latch clearance, and Door 2, 406 mm (16 in.) latch clearance, demonstrate...
-
304 Turning Space
Objects that provide sufficient knee and toe clearance can overlap a limited portion of the turning space. Comment....
-
Section 810.2.2
We note that there may be some instances in which it will be necessary to make operational adjustments where sufficient clearance is not available to permit the deployment of lifts or ramps...
-
4.2.6* SIDE REACH
If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig. 6(c). Figure 6 Side Reach...
-
Clear Floor Space [§309.2]
Clear Floor Space Additional clearance is required if the space is obstructed on three sides for more than half the depth to allow easier maneuvering into the space....
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
Lavatories Adjacent to Partitions
Per 11B-606.2, we know that a clear space positioned for a forward approach is required (with exceptions), with proper knee and toe clearance. ...
-
11B-608.2.3 Alternate roll-in type shower compartments
FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE...
-
Post-Mounted Objects [§307.3]
The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)....
-
Clear Floor Space [§309.2]
If clear floor space is obstructed on both sides more than half the minimum required depth, a wider clearance (36” min.) is required for maneuvering and sway....
-
Handrails [ADA Standards §504.6, §505]
Handrails [ADA Standards §504.6, §505] Specifications in the ADA Standards for handrail surfaces and clearances facilitate a power grip along the handrail length....
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
§ 38.125(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a seating location...
-
11B-1009.4.1 Clear deck space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
1009.4.1 Clear Deck Space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars....
-
410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
T503 Passenger Access Routes
In the 2016 Non-Rail Vehicle Guidelines, passenger access routes (which were referred to as “accessible circulation paths” in the proposed rule) must provide clearances sufficient to permit...
-
Furnishings and Equipment
In addition, placement of non-fixed elements can affect the accessibility of an area by encroaching into accessible routes and clearances....
-
11B-608.2.1 Transfer type shower compartments
Clearance of 36 inches (914 mm) wide minimum by 48 inches (1219 mm) long minimum measured from the control wall shall be provided....