ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
Search Results "Assurances from Contractors"
-
CHAPTER 10 MEANS OF EGRESS
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
ETA Editor's Note Sections from California Building Code Chapter 4 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted....
-
Technical Memorandum TM 2013-20 Valet Parking
October 3, 2010 2012 TAS Reference: 208 and 209.4 The 1994 TAS (and 1991 ADAAG) required valet parking facilities to provide a passenger loading zone but exempted the facilities from...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
CLEARANCE Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side unless noted) From...
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
-
Step 4: Calculate Cumulative Deviation Percentage
The first point of deviation occurs 400 feet (122 meters) from the trailhead and the vista is only 250 feet (76 meters) from the trailhead....
-
General Accommodations
should have 1) an operating phone, cell-phone, TTY, and two-way radio so that emergency services can be contacted; 2) a closing door; 3) supplies that enable individuals to block smoke from...
-
§ 38.159(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches (75 mm) or less above a 6 inch (150 mm) curb, a maximum slope of 1:4 is permitted; if the height of the vehicle...
-
§ 38.29(b)
(b) Handrails and stanchions shall be provided in the entrance to the vehicle in a configuration which allows persons with disabilities to grasp such assists from outside the vehicle while...
-
11B-604.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...
- EVSE Garage Overhead Charger with Integrated Payment Station Addressing EV Charging for Persons with Disabilities
-
Station Names: ADA Standard Section 810.6.3
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
Finish and Contrast: ADA Standard Section 703.7.1
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Numeric Keys: ADA Standard Section 707.6.2
The number five key shall be tactilely distinct from the other keys. Advisory 707.6.2 Numeric Keys....
-
Finish and Contrast: ADA Standard Section 703.5.1
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face of the curb between the...
-
11B-703.5.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.6.2 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-813.2.1.2 Clearance
End and side clearances shall be measured from the outermost extent of the table. Floor or ground surfaces of clearances shall comply with Section 11B-302....
-
11B-703.7.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-1009.3 Sloped entries
Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs...
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed....