A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
Search Results "Sloped Sidewalk"
-
1009.5.2 Transfer Space
-
4.7.5 Sides of Curb Ramps
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, it shall have flared sides; the maximum slope of the flare...
-
4.9.3 Nosings
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
4.9.3 NOSINGS
Risers shall be sloped or the underside of the nosing shall have an angle not less than 60 degrees from the horizontal....
-
1018.10 Dune Crossings
This section requires handrails complying with 505 of the Architectural Barriers Act Accessibility Guidelines and curbs or barriers to be provided where the slope of a beach access route...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Q4: Road Alteration Projects that Trigger Curb Ramp Improvements Not on State/Local Property
Q4: When a road alteration project triggers the requirement to install curb ramps, what steps should public (State or local) entities take if they do not own the sidewalk right-of-way needed...
-
Issue 9: Reach (how far?)
Figure 12 shows a location where new APS (and new sidewalks) were installed, but the APS are not usable....
-
Small governmental jurisdictions affected by proposed accessibility guidelines
., sidewalks, pedestrian street crossings, and pedestrian signals)....
-
General (R304.1) (Section-by-Section Analysis)
Blended transitions are raised pedestrian street crossings, depressed corners, or similar connections between the pedestrian access route at the level of the sidewalk and the level of the...
-
THE SETTLEMENT CLASS
to the City) with any mobility disability, who, at any time from the beginning of time through the thirty-year term of the Settlement Agreement: (1) accessed or attempted to access any sidewalks...
-
Roundabouts (Section-by-Section Analysis)
Where sidewalks are flush against the curb at roundabouts and pedestrian street crossing is not intended, a continuous and detectable edge treatment must be provided along the street side...
-
1134A.6 Showers
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
M303.3.2 Beveled (Section-by-Section Analysis)
proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required to be beveled with a slope...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
E. Chapter 4: Boarding and Alighting
Responses to comments on the Board’s proposal in the 2010 NPRM to revise the technical requirements for the slope of ramps in non-rail vehicles by specifying a single standard (1:6) for...
-
Dispersion
Clustering wheelchair spaces is allowed only where sight line slopes exceed 5%, such as bleachers and balconies (or in alterations where dispersion is technically infeasible)....
-
4(6)
The finished surface of this area that is located immediately outside the entry may be sloped, up to 1/8 inch per foot (12 inches), for drainage. ...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
f-v
[ADA Standards § 4.8.4] Yes No Note: if the running slope is less than 1:16 but more than 1:20, each ramp segment may be up to 40 feet long followed by a level landing]....
-
1132A.4, Item 4
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed....