Do access aisle borders (in blue) have to be painted on all four sides to be considered compliant?
I would say yes as the language in the code is pretty specific using the term "perimeter". I would also say that both of the "end" lines would/could be within the required length.
-
Attachment E
The sign shall be mounted on the wall adjacent to the latch side of the door with the centerline of the sign at 60 inches above the finished floor and situated such that a person can approach...
- Adaptive Engineering Inc. Mobilift CX Wheelchair Lift
-
Clear Floor and Turning Space Inside Examination Rooms
The exam table must have sufficient clear floor space next to it so that an individual using a wheelchair can approach the side of the table for transfer onto it....
-
Grab bar protocol
When transferring to a lower height, with the front grab bar available, and without side guard, 51% (59/115), CI[42%,60%] used the front bar, and 20% (23/111), CI[12%,25%] could transfer...
- Mariak Industries Motorized Window Coverings
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
11B-1009.5.2 Transfer space
by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-1008.3.1.3 Transfer space
The 48 inch (1219 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
604.8.3 Coat Hooks and Shelves
Coat hooks shall be located within one of the reach ranges specified in 308....
-
803.5 Coat Hooks and Shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....
-
G. Self-serve Items
counter is used for serving breakfast or other food products, does it have at least a 36" long section that is no higher than 36" above the floor to allow persons who use wheelchairs to reach...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
11B-608.2.2.1 Clearance
[2010 ADAS] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance...