significant changes to accommodate the unique challenges of mammography equipment; one significant change to the ramped running slope requirement; and a final significant change to the width...
Search Results "Continuous Width"
Commonly Searched Documents
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
-
Transfer Steps
Each transfer step must have a tread depth of 14 inches minimum to 17 inches maximum and a minimum tread width of 24 inches....
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting intervals...
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum and width...
-
7.4.11.1 Clear Space
The clear space shall not overlap the trail width but may overlap a resting space or passing space. The slope of the clear space shall not exceed 1:20 (5 percent) in any direction....
-
4.34.6.5(7)
The knee space shall have a clear width of 30 in (760 mm) and a clear depth of 19 in (485 mm)....
-
2.6 Passing Spaces
ORARs with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 2.6 at intervals of 200 feet (61 m) maximum....
-
Turning Space: ADA Standard Section 809.2.2
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
505.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
505.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
11B-505.6 Gripping surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
4. Comparison of Proposed Technical Provisions Applicable to Shared Use Paths and AASHTO Guide
A pedestrian access route shall be provided for the full width of a shared use path. 5.2.1 Width and Clearance The minimum paved width for a two-directional shared use...
- Sargent 8200 Lever Lock
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
§ 37.135(c)(2)
(2) In the event of any change in circumstances that results in an entity which has submitted a certification of continued compliance falling short of compliance with §§37.121-37.133, the...
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
The Access Board is considering adding exceptions in the final standards to the minimum width in M303.2.2 and the minimum depth in M303.2.3 for diagnostic equipment with wheelchair spaces...
-
"Existing Facility" (Section-by-Section Analysis)
It has been the Department's view that newly constructed or altered facilities are also existing facilities subject to title III's continuing barrier removal obligation, and that view is...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Trailers with Two Wheels
Width and length vary, although the majority are relatively small trailers used for carrying children....
-
4.34.6.4(4)
The knee space shall have a minimum clear width of 30 in (760 mm) and a minimum clear depth of 19 in (485 mm)....
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances