[See subsections ...]
Search Results "Play Area Ramp"
Commonly Searched Documents
-
Sec. 12207. Federal wilderness areas. [Section 508]
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
All public use and common use areas shall be accessible in compliance with this chapter....
-
3.2.5 Camp Living Areas
All constructed features provided in a camp living area shall comply with applicable provisions in sections 4.0 and 5.0....
-
203.9 Employee Work Areas
small work areas....
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.10 Wet Conditions
405.10 Wet Conditions. Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed.
-
4.1.6(3)(a)(i)
(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches.
-
405.10 Wet Conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
R207.2 Alterations
In alterations where existing physical constraints prevent compliance with R207.1, a single diagonal curb ramp shall be permitted to serve both pedestrian street crossings....
-
Elevator requirement to new dining area on the mezzanine of an existing facility
Let's also assume that the seating area of the mezzanine dining area you mention contains more than 25% of the total combined seating area and focus on the more difficult question you seem...
- Atlantis Railing
-
4.8.5(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top and bottom of the ramp segment and shall be parallel with the floor or ground surface (see Fig...
-
405.7.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum....
-
Section 406.8
maintain the status quo with respect to detectable warnings in pedestrian facilities, the Department is adding a provision (not found in the current version of the new ADAAG) requiring curb ramps...
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
§ 38.83(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches, with a safety factor...
-
8.2 Reading and Study Areas
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and...
-
8.2 READING AND STUDY AREAS
At least 5 percent or a minimum of one of each element of fixed seating, tables, or study carrels shall comply with 4.2 and 4.32. Clearances between fixed accessible tables and study...
-
1008.3.2 Transfer Steps
Transfer steps shall be provided where movement is intended from transfer platforms to levels with elevated play components required to be on accessible routes....
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...