Search Results "Door Opening Force"
- Besam Hurricane Resistant Automatic Sliding Door 1012493 SL500 SA Clean Room SS Narrow Stile Rev 2.0
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
- Hager Companies Round Door Push/Pull Set 20
- LaCantina Multi-slide Aluminum Sliding Door System
- Besam SL500 CGL Commercial Glass Entry Door - Fixed Sidelite SS BIM
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
- Panda TS.60 Thermally Broken Folding Door System
- Besam Hurricane Resistant Automatic Sliding Door 1011264 SL500 Clean Room OHC Fixed Sidelite SS Narrow Rev 3.0
- Besam Hurricane Resistant Automatic Sliding Door 1011265 SL500 Clean Room OHC Fixed Sidelite BP Narrow Rev 3.0
- Besam Hurricane Resistant Automatic Sliding Door 1011263 SL500 Clean Room OHC Full Breakout BP Narrow Rev 3.0
- Besam Hurricane Resistant Automatic Sliding Door 1011262 SL500 Clean Room OHC Full Breakout SS Narrow Rev 3
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
Vertical clearance shall be measured from the inside finished edge of the door opening to the highest point of the deployed lift, ramp or bridgeplate below....
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
-
1011.4, Item 2
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
1013.4, Item 2
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
- Access Board: Door Thresholds
- Hager Companies Round Offset Door Push/Pull Set 24Q
- Mockett DH401-BB Slim Barrel Door Handle Back to Back
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
-
NABCO GT 1400 Folding Door LH
Requires the Premium User plan or above. (Login or upgrade your account!)
-
GT 1400 Folding Door Bi Fold
Requires the Premium User plan or above. (Login or upgrade your account!)
-
404.2.4 Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4....
- Mockett DH5/BB Large Cylindrical Door Handle Back to back