203.11 Water Slides. Water slides shall not be required to comply with these requirements or to be on an accessible route....
Search Results "Water Closets"
Commonly Searched Documents
-
203.11 Water Slides
-
11B-607.6 Shower spray unit and water
Bathtub shower spray units shall deliver water that is 120°F (49°C) maximum. Advisory 11B-607.6 Shower spray unit and water....
-
4.16.1 General
Accessible water closets shall comply with 4.16....
- Figure 604.2 Water Closet Location – Drawing from the U.S. Access Board
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
Water Flow Height
The proposed rule required spouts to provide a flow of water at least 4 inches high "to allow the insertion of a cup or glass."...
-
1134A.7, Item 1
The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Water Hydrants
The surface at the base of water hydrants at recreation areas must be firm and stable with a 60-inch turning radius. See the "Surfaces" rule of thumb above....
-
F203.11 Water Slides
Water slides shall not be required to comply with these requirements or to be on an accessible route....
-
203.11 Water Slides
Water slides shall not be required to comply with these requirements or to be on an accessible route....
-
1134A.7, Item 1
The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
Are closet doors and pantry doors required to comply?
Doors serving walk-in closets or pantries must comply....
-
4.7.7 Water Spouts
Water spouts shall be located in the space so that the water spout is 11 inches (280 mm) minimum and 12 inches (305 mm) maximum from the rear center of the long side of the clear floor or...
-
Zurn Model Z1209 Vertical Offset Siphon Jet Water Closet Support System
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604.5 Grab bars
Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
602.6 Water Flow
602.6 Water Flow. The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
11B-608.6 Shower spray unit and water
Shower spray units shall deliver water that is 120°F (49°C) maximum....
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....