TACTILE WARNING
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
11B-247.1.2.4 Bus stops
Where detectable warnings are provided at bus stop boarding and alighting areas in compliance with Section 11B-810.2.3, detectable warnings shall comply with Sections 11B-705.1.1 and 11B...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.2.4 Bus stops
When detectable warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches...
-
11B-705.1.1.4 Resiliency
Detectable warning surfaces shall differ from adjoining surfaces in resiliency or sound-on-cane contact....
-
11B-705.1.1.4 Resiliency
Detectable warning surfaces shall differ from adjoining surfaces in resiliency or sound-on-cane contact....
-
a) Curb Ramps
a) Curb Ramps 48....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
4.29.6 Detectable Warnings at Reflecting Pools
4.29.6 Detectable Warnings at Reflecting Pools. The edges of reflecting pools shall be protected by railings, walls, curbs, or detectable warnings complying with 4.29.2....
-
11B-247 Detectable warnings and detectable directional texture
[See subsections ...]
-
11B-247 Detectable warnings and detectable directional texture
[See subsections ...]
-
11B-406.5.3 Landings
[2010 ADA Standards] EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12. ...
-
11B-406.5.3 Landings
[2010 ADA Standards] EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12. ...
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
11B-705 Detectable warnings and detectable directional texture [2010 ADAS] 705 Detectable Warnings...
-
11B-705 Detectable warnings and detectable directional texture
11B-705 Detectable warnings and detectable directional texture. [2010 ADAS] 705 Detectable Warnings...
-
11B-705 Detectable warnings and detectable directional texture
11B-705 Detectable warnings and detectable directional texture [2010 ADA Standards] 705 Detectable Warnings...
-
4.29.3 Detectable Warnings on Doors To Hazardous Areas
4.29.3 Detectable Warnings on Doors To Hazardous Areas. (Reserved)....
- Detectable Warning Systems, Inc. AlertCast® Detectable Warning
-
11B-705.1.2.7 Track crossings