A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
Search Results "Vanity Centerline"
-
11B-809.10.8.2 Floor space
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-809.9.1 Clear floor space
Clear floor spaces 30 inches (762 mm) by 48 inches (1219 mm), with centerlines aligned with the centerline of the work surface, appliance, sink or fixture, shall be provided in the following...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
test response
I've used this product to help during barrier removal on toilets that aren't mounted correctly: http://www.zurn.com/Pages/ProductDetails.aspx?NodeKey=373628 This product has...
-
4.17.6 Grab Bars
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided. Grab bars may be mounted with any desired method as long as they have a...
-
4.17.6 GRAB BARS
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided. Grab bars may be mounted with any desired method as long as they have a...
-
7(2)(b)(iv)
The other (non-grab bar) side of the toilet fixture is a minimum of 1'3" from the finished surface of adjoining walls, vanities or from the edge of a lavatory. (See Figure 7(a).)...
-
4.17.3* Size and Arrangement
The size and arrangement of the standard toilet stall shall comply with Fig. 30(a), Standard Stall. Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a))...
- American Standard AccessPRO Toilet
-
Accessible Parking Space
Accessible Parking Space
- Figure 604.5.2 Rear Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
-
Lavatories Adjacent to Partitions
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
Re: 604.2 Water Closet Location
-
Van Accessible Parking Spaces [§502.1 - 502.5]
Van Accessible Parking Spaces [§502.1 - 502.5] At least one space for every 6 or fraction of 6 accessible spaces must be van accessible. Van spaces provide an additional 3...
-
Wall furr-out to support a grab bar when toilet is too far from the side wall
Here's a good example of one solution for a water closet that's too far from the adjacent side wall. Sometimes this solution is easier than moving the fixture when an offset flange...
-
Lavatory Fixtures and Vanities
The proposed rule included references to "lavatory fixtures" and to "vanities." Commenters indicated that such references were redundant or inaccurate and should be removed....
-
11B-604.9 Water closets and toilet compartments for children's use
SECTION TITLE NOTES 11B-604.9 Water closets and toilet compartments for children's...
- Rakks® EHV Vanity Supports
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
1134A.8 Lavatories, vanities, mirrors and towel fixtures. Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
- AJW Architectural Products U480 Round Waste Chute - Vanity Mounted