Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No...
Search Results "Toilet Compartment"
Commonly Searched Documents
-
H17
-
11B-604.9.1 Location
the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible toilet...
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Standard Stall
Different people use different techniques in transferring from a wheelchair to the toilet seat....
-
11B-604.8.1.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.1.4 Toe clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
11B-604.8.1.4 Toe clearance
Compartments for children’s use shall provide a toe clearance of 12 inches (305 mm) minimum above the finish floor....
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
Size and Clearances for Shower Compartments: ADA Standard Section 608.2
Section 608.2 covers the current ADA Standards for the size and clearances of shower compartments.
-
11B-604.9 Water closets and toilet compartments for children's use
11B-604.9 Water closets and toilet compartments for children's use. Water closets and toilet compartments for children's use shall comply with Section 11B-604.9....
-
4.17.4 Toe Clearances
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater...
-
11B-604.9 Water closets and toilet compartments for children's use
Water closets and toilet compartments for children's use shall comply with Section 11B-604.9. [2010 ADAS] Advisory 604.9 Water Closets and Toilet Compartments for Children's Use. ...
-
11B-608.2 Size and clearances for shower compartments
Shower compartments shall have sizes and clearances complying with Section 11B-608.2....
- Hadrian Inc. Powder Coated Toilet Partition
-
Toilet Rooms South (Briefing Theater)
Toilet Rooms South (Briefing Theater): jj....
-
Toilet and Bathing Facilities: ADA Standard Section 807.2.4
Toilet facilities or bathing facilities that are provided as part of a cell shall comply with 603....
-
11B-604.9 Water closets and toilet compartments for children's use
Water closets and toilet compartments for children's use shall comply with Section 11B-604.9....
-
Plumbing Fixtures and Accessories: ADA Standard Section 213.3
Section 213.3 covers scoping requirements in the current ADA Standards for plumbing fixtures and accessories.
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
Toilet Rooms North (Celebrity Spies)–Men [sic]: dd....
-
11B-213.3 Plumbing fixtures and accessories
Plumbing fixtures and accessories provided in a toilet room or bathing room required to comply with Section 11B-213.2 shall comply with Section 11B-213.3....
-
Toilet Facilities and Bathing Facilities: ADA Standard Section 809.4
Toilet and bathing fixtures required to comply with 603 through 610 shall be located in the same toilet and bathing area, such that travel between fixtures does not require travel between...