The highest operable part of controls, dispensers, receptacles, and other operable equipment shall be placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6....
Search Results "Reach Range"
Commonly Searched Documents
-
4.27.3* Height
-
A4.27.3 Height
Electrical receptacles installed to serve individual appliances and not intended for regular or frequent use by building occupants are not required to be mounted within the specified reach...
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception: Reserved....
-
11B-1008.4.2 Clear floor or ground space
The following table provides guidance on reach ranges for children seated in wheelchairs. These dimensions apply to either forward or side reaches....
-
4.34.3(1) Forward Approach Only
If only a forward approach is possible, operable parts of all controls shall be placed within the forward reach range specified in 4.2.5....
-
Clear Floor Space [4.25.2] and Height [4.25.3]
However, since people who use wheelchairs may not be able to reach beyond the toes, a forward reach is generally limited to those storage elements providing knee and toe clearances....
-
11B-308.3 Side reach
[See subsections ...]
- Figure 308.3.2 Obstructed High Side Reach – Drawing from the U.S. Access Board
-
4.34.3(3) Forward and Parallel Approach
If both a forward and parallel approach are possible, operable parts of controls shall be placed within at least one of the reach ranges in paragraphs (1) or (2) of this section....
-
Guidelines for Requirement 5
The ANSI Standard presents reach ranges for both forward and side approaches for two situations: (1) unobstructed; and (2) over an obstruction. ...
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
Forward Approach
Forward Approach A maximum height of 48 inches is required for a forward reach....
-
407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in 308, measured to the centerline of the highest operable part....
-
T304.2 Height
Operable parts shall be located 24 inches (610 mm) minimum and 48 inches (1220 mm) maximum above the floor of non-rail vehicles.
-
Do reach range requirements apply to elements or only to operable parts of elements?
Reach range requirements apply to the operable portions of elements, including handles, controls, switches, buttons, control pads and other mechanisms that must be activated or manipulated...
- Access Board: Reach Ranges
-
Knee and Toe Clearances
[See subsections ...]
-
11B-308.2 Forward reach
[See subsections ...]
-
Issue 9: Reach (how far?)
Issue 9: Reach (how far?) APS devices can be located in landscaped areas if the pushbutton is reachable from a level paved area....
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....