Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
Search Results "Fixed Bench"
-
11B-813.2.1 Adult changing table
-
Minimum Rear Wall Required.
It appears that this comment references the 2010 ADA Standards for Accessible Design for minimum bench length (42") but uses the CA - 2013 minimum bench length (48") to develop the minimum...
-
11B-903.4 Back support
The bench shall provide for back support or shall be affixed to a wall....
-
11B-903.4 Back support
The bench shall provide for back support or shall be affixed to a wall....
- Landscape Forms Inc. Gus Bench Collection
-
Fixed Shower Head Height
The original ADAAG allowed fixed shower heads 48 inches high maximum to be used instead of the required hand-held unit in "unmonitored facilities where vandalism is a consideration."...
-
Seat Height
The proposed rule specified that the bench seat be 17 to 19 inches above the floor or ground (903.4)....
- Landscape Forms Inc. Washington Square Bench Collection
-
4.35.4 Bench
Every accessible dressing room shall have a 24 in by 48 in (610 mm by 1220 mm) bench fixed to the wall along the longer dimension....
-
§ 37.101(b) Fixed Route System. Vehicle Capacity Over 16
(b) Fixed Route System. Vehicle Capacity Over 16....
-
§ 37.101(c) Fixed Route System. Vehicle Capacity of 16 or Fewer
(c) Fixed Route System. Vehicle Capacity of 16 or Fewer....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
- Access-Able Designs Child Dressing Bench CH-101
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
Wheelchair Space for Seat Transfer
The proposed rule specified that the wheelchair space be positioned so that it provides a parallel approach to an end of the bench seat (903.2)....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
- Access-Able Designs Adult Dressing Bench D-101-42
-
Bus Shelter Benches
John, I cannot find anything that says that benches in bus shelters must comply with the bench requirements in 903. ...