1132A.3 Width and height of interior doors and secondary exterior doors. Doors shall comply with the following:...
Search Results "Exterior Stair"
Commonly Searched Documents
-
1132A.3 Width and height of interior doors and secondary exterior doors
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Alterations to stairs (Section-by-Section Analysis)
Alterations to stairs....
-
Alterations to stairs. (Section-by-Section Analysis)
Alterations to stairs....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
1011.11 Handrails
... [DSA-AC] For applications listed in Section 1.9.1 regulated by the Division of the State Architect-Access Compliance, see Chapter 11B, Sections 11B-504.6 and 11B-505.
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
Stairs, short-term list
I’ll put one up there, short-term, stairs....
-
Opening Force
No maximum opening force was proposed for exterior hinged doors....
-
1009.6.2 Handrails
Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
1009.6.2 Handrails
Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
1009.6.2 Handrails
Handrail extensions required by 505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
Handrail extensions required by Section 11B-505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
Handrail extensions required by Section 11B-505.10.3 shall not be required on pool stairs....
-
11B-1009.6.2 Handrails
Handrail extensions required by Section 11B-505.10.3 shall not be required on pool stairs....
-
504.5 Nosings
The radius of curvature at the leading edge of the tread shall be 1/2 inch (13 mm) maximum. Nosings that project beyond risers shall have the underside of the leading edge curved or...
-
4.9.3 Nosings
The undersides of nosings shall not be abrupt. The radius of curvature at the leading edge of the tread shall be no greater than 1/2 in (13 mm). Risers shall be sloped or the...
-
4.9.3 NOSINGS
The undersides of nosings shall not be abrupt. The radius of curvature at the leading edge of the tread shall be no greater than 1/2 in (13 mm). Risers shall be sloped or the...
-
F217.4.4 Exterior Site Requirement
Where four or more public pay telephones are provided on an exterior site, at least one public TTY shall be provided on the site....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
1009.7 Exterior areas for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....