Handrails shall be continuous within the full length of each stair flight or ramp run....
Search Results "Exterior Stair"
Commonly Searched Documents
-
505.3 Continuity
-
Outdoor Conditions [4.8.8]
Exterior ramps must be designed so that water does not accumulate on the ramp or landing surface. A slope up to 2% is allowed at landings for adequate drainage....
- Seton Custom SetonGlo™ Floor & Stair Identification Signs AV0154
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water. ...
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior...
-
504.7 Wet Conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
1132A.4, Item 2
Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½...
-
4.9.4(5)
(5) Top of handrail gripping surface shall be mounted between 34 in and 38 in (865 mm and 965 mm) above stair nosings....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
A number of commenters from the building industry objected to the provision of the Option One guidelines that specified that an exterior deck, balcony, patio, or similar surface may be no...
-
R408.5 Nosings
R408.5 Nosings. The radius of curvature at the leading edge of the tread shall be 13 mm (0.5 inch) maximum. Nosings that project beyond risers shall have the underside of the leading...
-
R408.6 Handrails
R408.6 Handrails. Stairways shall have handrails complying with R409.
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
11B-504.4 Tread surface
Stair treads shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....