Section 216.9.2 covers scoping requirements in the current ADA Standards for TTY directional signs.
Search Results "EVCS Signage"
Commonly Searched Documents
-
Directional Signs: ADA Standard Section 216.9.2
-
11B-216.9.2 Directional signs
Directional signs indicating the location of the nearest public TTY shall be provided at all banks of public pay telephones not containing a public TTY. In addition, where signs...
- Innerface Trio Interior Signage
-
11B-812.5.5 Obstructions
EVCS shall be designed so accessible routes are not obstructed by cables or other elements....
-
11B-812.5.5 Obstructions
EVCS shall be designed so accessible routes are not obstructed by cables or other elements....
-
11B-228.3.2 Minimum number
Where EVCS are provided in more than one facility on a site, the number of EVCS complying with Section 11B-228.3.2 provided on the site shall be calculated according to the number required...
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
- 703.4.1 Raised Letter and Braille Signage Height
-
Signage
Signage Signage must be provided at the entrance of the queue or waiting line for each accessible amusement ride to identify the type of access provided on the ride (e.g., rides with...
-
Directional and Informational Signs: ADA Standard Section 216.3
Section 216.2 covers scoping requirements in the current ADA Standards for directional and informational signs.
-
11B-216.3 Directional and informational signs
Signs that provide direction to or information about interior and exterior spaces and facilities of the site shall comply with Section 11B-703.5. [2010 ADA Standards] 216.3...
- Takeform Fusion Signage Floor Directional Type B
-
11B-812.5.4 Arrangement
Exceptions: Ambulatory EVCS shall not be required to comply with Section 11B-812.5.4....
-
TTYs: ADA Standard Section 216.9
Section 216.9 covers scoping requirements in the current ADA Standards for signs for TTYs.
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2).
-
11B-216.9 TTYs
Identification and directional signs for public TTYs shall be provided in accordance with Section 11B-216.9.
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities. The circle symbol shall contrast with the...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
- Takeform Fusion Signage Floor Directional Type B.2
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....