Section 100.205 of the Fair Housing regulations incorporates the Act's design and construction requirements, including the requirement that multifamily dwellings for first occupancy after...
Search Results "Dwelling Unit (FHA)"
Commonly Searched Documents
-
3. Discussion of Comments on Related Fair Housing Issues Compliance Deadline
-
Identification: ADA Standard Section 809.5.5.2
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-233.3.1.2.2 Ground floor residential dwelling units
Ground floor residential dwelling units shall be adaptable. A building may have one or more ground floors....
-
Compliance Determinations by State and Local Jurisdictions
A few commenters questioned the role of States and units of local government in determining compliance with the Act's accessibility requirements....
-
Requirement 6. Reinforced walls for grab bars.
Section 100.205(c)(3)(iii) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
Minimum Number: New Construction: ADA Standard Section 233.3.1
Newly constructed facilities with residential dwelling units shall comply with 233.3.1....
-
Guidelines for Requirement 6
a powder room is subject to the requirement for reinforced walls for grab bars when the powder room is the only toilet facility located on the accessible level of a covered multistory dwelling...
-
106.5.54 Residential Dwelling Unit
A unit intended to be used as a residence that is primarily long-term in nature....
-
§100.205(d)
All 100 units are covered multifamily dwelling units and they all must be designed and constructed so that they comply with the accessibility requirements of paragraph (c) of this section...
-
Additional Parking Spaces for Residents: ADA Standard Section 208.2.3.2
Section 208.2.3.2 covers scoping requirements in the current ADA Standards for additional parking spaces for residents.
-
11B-208.2.3.2 Additional parking spaces for residents
Where the total number of parking spaces provided for each residential dwelling unit exceeds one parking space per residential dwelling unit, 2 percent, but no fewer than one space, of all...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a...
-
4(2)
(2) In single-story dwelling units, changes in level within the dwelling unit with heights between 1/4 inch and 1/2 inch are beveled with a slope no greater than 1:2....
-
Section 3. Fair Housing Act Design and Construction Requirements
This section reprints §100.205 (Design and Construction Requirements) from the Department's final rule implementing the Fair Housing Act. A reprint of §100.205 was included to...
-
3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
-
11B-208.3.3.1
Detached private garages accessory to residential dwelling units, shall be accessible as required by Section 11B-208.3....
-
11B-233.3.4.2 Alterations to individual residential dwelling units
to the altered residential dwelling units until the total number of residential dwelling units complies with the minimum number required by Sections 11B-233.3.1.1, and 11B-233.3.1.3....
-
Bathroom Design Illustrations
Comment. A number of commenters from the disability community stated that two of the six bathroom drawings in the preamble to the proposed guidelines (numbers 4 and 6 at 55 FR...
-
Activation: ADA Standard Section 809.5.2.1
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
The interior of the main entry door is part of the dwelling unit and only needs to meet the requirements for usable doors within the dwelling intended for user passage, i.e., at least 32...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall...
-
Accessible Routes: ADA Standard Section 809.2
Accessible routes complying with Chapter 4 shall be provided within residential dwelling units in accordance with 809.2....
-
11B-809.2 Accessible routes
Accessible routes complying with Division 4 shall be provided within residential dwelling units in accordance with Section 11B-809.2....